    How to install the fan using the Vibration-Compensators?
    First, pull the Vibration-Compensators through the mounting holes of the case. Then put the fan onto the Vibration-Compensators and pull them through the mounting holes of the fan.

    Vibration Compensators Installation


    Can I use Noctua fans on my fan controller?
    In general, our fans can be used with any fan controller. There is a known compatibility issue with the Zalman ZM-MFC2 controller though: This product uses Pulse Width Modulation (PWM) in order to control the fan speed and the unfavourable carrier frequency of the PWM signal can create an oscillation when used with certain fans. This will result in the fan speeding up and down. We therefore recommend not using the Zalman ZM-MFC2 with our fans.

    My fan doesn’t spin when I start up the PC - is it faulty?
    If you've connected the fan directly (or using the supplied Low-Noise or Ultra-Low-Noise-Adaptors) to your mainboard, it's possible that the mainboard's automatic fan controller doesn't provide the required starting voltage due to the low CPU temperature. Please verify whether the fan starts spinning at higher CPU temperatures, remove any Low-Noise or Ultra-Low-Noise Adaptors, deactivate your mainboard's automatic fan controller in the BIOS or connect the fan directly to the power supply using the supplied 3:4-pin adaptor.

    Can I run Noctua fans on 4-pin PWM connectors and use my mainboard’s automatic fan controller?
    You can simply connect our fan's 3-pin connector to the 4-pin PWM sockets of today's mainboards so that the fourth pin that transmits the PWM signal is left blank (due to the shape of the connector, there's no danger of reversing polarity). Some mainboards (e.g. current Gigabyte models) are capable of controlling fans not only via PWM, but also by adjusting the supplied voltage. In some cases, this may require you to change BIOS options like "Fan Control Mode" from "PWM" to "Voltage" or "Analog". Please consult your mainboard's manual in this regard. However, some mainboards use an "auto" setting by default that automatically chooses PWM or voltage based regulation according to the connected fan. Automatically controlling the fan speed may not possible on mainboards that pulse the power rather than lowering the fan voltage.

    PWM PWM





    Avez-vous une question sur un de nos produits ? Veuillez utiliser ce formulaire pour poser une question !

Noctua
16.09.2014 - HardwareHeaven.com NH-D15
Verdict du test: "Excellent thermal performance, decent noise levels and great looks. The Noctua NH-D15 wins our performance award." (Stuart Davidson, HardwareHeaven.com)
Submit

16.09.2014 - 4Tech.be NH-D15
Verdict du test: "Noctua heeft met de NH-D15 weer laten zien dat het heer en meester is op het gebied van luchtkoeling. De NH-D15 weet ontzettend goede prestaties neer te zetten op zowel het gebied van koeling als geluidsproductie. Hij weet in ieder geval veel waterkoelsetjes te evenaren of zelfs voorbij te streven." (Henk van Hest, 4Tech.be)
Submit

16.09.2014 - Hardware.Info NH-U14S
Verdict du test: "Misschien wel dé verrassing van deze test: hoe kan een koeler die slechts 8 centimeter diep is vrijwel net zo goed koelen als gevaartes als de Noctua NH-D15? Deze Noctua U14S staat qua koelprestaties in de top 4, neemt niet veel plek in en is ook nog redelijk stil." (Koen Crijns, Hardware.Info)
Submit

15.09.2014 - BigBruin.com NH-D15
Verdict du test: "Considering that this cooler exceeded the cooling performance of the NH-U12S and the NH-U14S, and matched if not exceeded the low noise production of both, the Noctua NH-D15 heatpipe tower CPU cooler has to receive the Bigbruin.com 'Recommended' and 'Whisper Quiet' awards." (Richard Jackson, BigBruin.com)
Submit